Exide INVA TUBULAR

Presenting, Exide INVA TUBULAR 400, 500 AND 750 – this next generation tubular batteries designed specially to withstand long and frequent power interruptions. The ULTIMATE INVERTER BATTERIES.

Features of EXIDE INVA TUBULAR Range of Batteries

  • Ironclad® Tubular Technology
  • Electrolyte level indicator
  • High Acid volume per ampere hour
  • Deep cycle design
  • Resistance to abuse
  • Tower type design
  • Common Side Venting
  • Conforma to IS 13369 – 1992
  • Advantages

    Very long life | User friendly | Acide volume per ampere hour is 30% more than that of ordinary tubular batteries. It acts as a coolant and also ensures very low maintenance | Suited for use in areas of frequent power cuts (800 to 1000 cycles of deep discharge as against 300 / 400 cycle of other batteries | Can withstand overcharge better | Occupies less floor space, totally new look | Less pollution, environment friendly | Ensures consistent quality

    Model Capacity when discharged at C20 upto 1.75 vpc Dimension (+ / - 3mm) Weight (Kg + / -5%) Volume of Electrolyte ( 1.220 Sp. Gr.)
    Liters / Cell
    Initial charge Minimum AH input (AH) Initial Charge of Constant Current (A) Constant Potential Limiting Current (Amps) Trickle Charge (Current in mA)
    Length Width Height * Dry Filled Start (upto 2.36 vpc) Finish (upto 2.75 vpc) Min. Max.
    IT 400 115 Ah 500 187 416 29.00 53.80 3.38 450 12.0 6.0 25 100 400
    IT 500 150 Ah 500 187 416 33.77 59.81 3.43 540 14.4 7.2 30 120 480
    IT 750 200 Ah 500 187 416 41.44 66.00 3.30 810 21.6 10.8 45 180 720
    * The height mentioned is upto terminal top. *At 27˚C when discharged at C20 upto 1.75 vpc (1.250 sp. gr)
     

    Normal Recharging Instructions
    Recharging through Inverter at constant potential mode of 14.4V with limited current as specified. After battery potential reaches 14.4V, the battery should continue in float charge mode at constant potential of 13.5V.

    Electrical Load System Voltage Reco. Inverter Rating Recommended Battery for Different
    Back-up time
          5 Hrs. 4 Hrs 3 Hrs. 2 Hrs. 1 Hrs.
    4 Tube + 4 Fan 12 650 VA 2P IT750 2P IT500 2P IT400 IT 750 IT400
    4 Tube + 5 Fan + 1TV 12 850 VA 3P IT750 2P IT750 2P IT750 2P IT500 IT750
    8 Tube + 9 Fan + 1TV 24 1450 VA 2S X 2P IT750 2S X 2P IT750 2S X 2P IT500 2S IT750 2S IT500
     

    NOTE: If the limit current of one battery is 'A' amp, for 'N' no. batteries in parallel, the limit current for charging of inverter should be AxN amp, Otherwise there will be problem during charging in parallel connection. This point should be taken in consideration before putting batteries in parallel combination.

    S = Series connection; P = Parallel connection.
    E.g. 3P X 2S = A string containing 2 nos. batteries in series and 3 nos. such strings in parallel.

    Statutory Notice:
    All batteries contain lead, which is harmful for humans and environment. As per statutory requirements, the used battery must be returned to the authorized dealer, manufacturer or at the designated collection centres.